<Command>
<Name>pvac</Name>
<Description>
<DescriptionText><text>
This is an easy way of reading the picker vacuum and/or turning it on or off.
"pvac" on it's own returns the current picker vacuum reading.
"pvac on" turns the vacuum on immediately, "pvac off 5" waits 5 seconds then
turns the vacuum off. This is useful for removing a plate from the picker nicely.
</text></DescriptionText>
</Description>
<AppliesTo>
<UnnumberedList>
<ListItem><TextApplies>Platesetter_3244</TextApplies></ListItem>
</UnnumberedList>
</AppliesTo>
<Syntax>
<NumberedList>
<ListItem><Text>
pvac on|off &lt;delay&gt;
</Text></ListItem>
</NumberedList>
</Syntax>
<Notes>
<DescriptionText><text>
</text></DescriptionText>
</Notes>
<SeeAlso>
<UnnumberedList>
<li>NVS:  </li><li><Link><LinkAddress>../nvs/sat_cal_pvt.xml</LinkAddress><LinkTitle>NVS: sat pvt</LinkTitle></Link></li>
<li><Link><LinkAddress>../commands/uvac.xml</LinkAddress><LinkTitle>Command: uvac</LinkTitle></Link></li>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:39:15 2008 PST
</Updated>
<Links>
</Links>
</Command>